8
Power Measurement
Uncertainty
± 5% of full scale average power
(95% c.l.)
Peak Power Measurement, 43 Elements only, Forward
direction only
Pulse Width, Min
2 – 25 MHz
25 – 100 MHz
> 100 MHz
15 µs
1.5 µs
800 ns
Rep. Rate, Min 15 pps
Duty Cycle, Min 1 x 10
–4
Uncertainty
b
± 8% of full-scale peak envelope
power (95% c.l.)
Match Measurement
Match Range
Return Loss
Rho (
ρ)
VSWR
0 to 20 dB
0.1 to 1
1.22 to 99.99
Uncertainty Twice the Avg Power Uncertainty
(Calculated from forward and
reflected uncertainty)
Settling Time, Max 2.5 seconds
Impedance, Nominal 50 ohms
Insertion Loss, Max 0.05 dB up to 1 GHz
Input VSWR, Max. 1.05:1 up to 1 GHz
Directivity, Typicala 30 dB
RF Connectors QC Type (N(F) normally supplied)
Power Supply From host instrument via cable