Bird-technologies 5000-EX Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Instrumentos de medición Bird-technologies 5000-EX. Bird Technologies 5000-EX User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - MODEL 5000-EX

INSTRUCTION BOOKDIGITAL POWER METERMODEL 5000-EX©Copyright 2008 by Bird Electronic CorporationInstruction Book P/N 920-5000-EX Rev. GTHRULINE® is a Re

Pagina 2 - I am not blank

Bird Model 5000-EX Digital Power MeterviiiAbout This ManualThis instruction manual guides users through the operation and maintenance of the Bird 5000

Pagina 3 - Safety Precautions

ixInstallation — Gives directions for connecting the DPM, and discusses the various power sources. Operation — Explains how to make measurements with

Pagina 4

xTable of ContentsSafety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . iAbout This Manual . . . . . . . . . . . . . . . . . . .

Pagina 5

1Chapter 1 IntroductionItems Supplied1. Bird Digital Power Meter (DPM)2. AC Mains Adapter3. Instruction Book4. 9-pin Serial CableOptional EquipmentDir

Pagina 6

Bird Model 5000-EX Digital Power Meter2Wideband Power Sensor (WPS)Bird 5012 Thruline Sensor that does not require elements. Can measure average, peak,

Pagina 7

Introduction3Component DescriptionFigure 1Component DescriptionDigital Power MeterModel5000-EXSHIFT21345678910111213

Pagina 8

Bird Model 5000-EX Digital Power Meter41. Speed Keys Activates the command displayed above it.2. Backlight Key Turns the backlight on momentarily.3. O

Pagina 9

Introduction5Display Description Note: Numbers in parentheses (1) refer to the labeled parts of the display above.- Display (1)The DPM-EX has two mea

Pagina 10 - About This Manual

Bird Model 5000-EX Digital Power Meter6- Battery Level Indicator (3) When the external adapter is connected, the indicator blinks until the battery is

Pagina 11

Introduction7Speed Keys- Scale For element-based sensors, sets the forward full scale power. This is listed on the forward element’s name-plate. Refle

Pagina 13 - Chapter 1 Introduction

Bird Model 5000-EX Digital Power Meter8

Pagina 14

9Chapter 2 InstallationPower SupplyThe DPM uses a rechargeable Nickel-Metal Hydride battery pack. Charge life is about 20 hours with the Bird WPS, 50

Pagina 15 - Component Description

Bird Model 5000-EX Digital Power Meter10ConnectionsWARNINGNever attempt to connect or disconnect RF equipment from the transmission line while RF powe

Pagina 16 - Enter offset values in dB

Installation11Directional Power Sensor (DPS)Connect the Bird DPS to the “Sensor” port on the DPM using the sensor cable provided.Connect the DPS to th

Pagina 17 - .0.0.0.0.0

Bird Model 5000-EX Digital Power Meter12Terminating Power Sensor (TPS)Connections are the same for the Bird TPS and TPS-EF. Connect the TPS to the “Se

Pagina 18 - - Power Indicator (10)

13Chapter 3 OperationThe Bird Digital Power Meter is very easy to operate. Once a sensor is connected, turn the DPM on and take a reading. Additional

Pagina 19 - Speed Keys

Bird Model 5000-EX Digital Power Meter14DPM ShutdownWhen Powered by Internal BatteriesTo shut down the DPM when it is powered from its internal batter

Pagina 20

Operation15" Press Scale." Change the units with the Fwd Units key until the DPM units match the units on the forward element." Use the

Pagina 21 - Chapter 2 Installation

Bird Model 5000-EX Digital Power Meter16TPS-EFThe Bird TPS-EF uses frequency correction factors to allow more accurate measurements. Look at the label

Pagina 22 - Connections

Operation17Selecting MeasurementThe Bird Wideband Power Sensor can measure Aver-age, Peak, and Burst power as well as Crest Factor and CCDF. To select

Pagina 23 - Orientation

iSafety PrecautionsThe following are general safety precautions that are not necessarily related to any specific part or proce-dure, and do not necess

Pagina 24

Bird Model 5000-EX Digital Power Meter18Average ModeThis mode displays the average forward and reflected power. In average mode, the VSWR or system ma

Pagina 25 - Chapter 3 Operation

19Chapter 4 MaintenanceCleaningClean the Bird Digital Power Meter and its display with a soft cloth dampened with mild detergent and water only. Clean

Pagina 26 - DPM Shutdown

Bird Model 5000-EX Digital Power Meter20TroubleshootingPROBLEMPOSSIBLE CAUSEREMEDYNothing shown on displayUnit is off Momentarily press the ON key.Bat

Pagina 27 - Operation

Maintenance21Erratic power readingsElement contact out of alignment (DPS)Align the contact. It must be far enough out to make good contact with the el

Pagina 28 - Wideband Power Sensor (WPS)

Bird Model 5000-EX Digital Power Meter22Battery ReplacementThe Nickel-Metal Hydride (Ni-MH) batteries do not normally need to be replaced. If necessar

Pagina 29

Maintenance23" Lay the DPM, display side down, on a clean surface." Use a small screwdriver to remove all six screws from the back cover.&qu

Pagina 30

Bird Model 5000-EX Digital Power Meter24Customer ServiceAny maintenance or service procedure beyond the scope of those in this chapter should be refer

Pagina 31 - Chapter 4 Maintenance

Maintenance25Parts ListPart Name Part NumberDigital Power Meter 5000-EXAC adapter120V ac230V ac5A22295A2226Cigarette Lighter Adapter 5A2238-1Direction

Pagina 32 - Troubleshooting

Bird Model 5000-EX Digital Power Meter26Attenuators & AccessoriesN(F) – N(M) Attenuators (RF power range with TPS)30 dB (10 mW – 10 W)40 db (100 m

Pagina 33 - POSSIBLE

Maintenance27SpecificationsBird 5000-EX Digital Power MeterDisplay Backlit LCD with major and minor digital displays, analog bar graph, and speed key

Pagina 34 - Battery Connector

Bird Model 5000-EX Digital Power MeteriiSafety Earth GroundAn uninterruptible earth safety ground must be sup-plied from the main power source to test

Pagina 35 - Maintenance

Bird Model 5000-EX Digital Power Meter28Bird 5010B Directional Power SensorSensor Type Bird Thruline directional two-element line section.Elements APM

Pagina 36 - Customer Service

Maintenance29Match MeasurementMeasurement RangeReturn LossRho (ρ)VSWR0 to 20 dB0.1 to 11.22 to 99.99Uncertainty Calculated from forward and reflected

Pagina 37 - Parts List

Bird Model 5000-EX Digital Power Meter30Bird 5011 and 5011-EF Terminating SensorsGeneral Corrected terminated average powerSensor Type Diode based ter

Pagina 38 - Adapters

Maintenance31Temp, Operating –10 to +50 °C (14 to 122 °F)Temp, Storage –40 to +80 °C (–40 to +176 °F)Mechanical Shock IAW MIL-PRF-28800F class 3Vibrat

Pagina 39 - Specifications

Bird Model 5000-EX Digital Power Meter32Bird 5012 Wideband SensorSensor CharacteristicsFrequency Range 350 MHz to 4 GHzRF Power Range 0.15 W – 150 W A

Pagina 40

Maintenance33Average PowerMatch MeasurementPeak Envelope PowerRF Power Range 0.15 – 150 WPeak/Average Ratio, Max 12 dBMeasurement Uncert. ± (4% of rea

Pagina 41

Bird Model 5000-EX Digital Power Meter34Figure 6Match Measurement UncertaintyFigure 7Max. Peak Power0–5–10–15–20–25Return Loss (dB)420–2–4–6Uncertaint

Pagina 42

Maintenance35Burst Average PowerCrest FactorComplementatry Cumulative Distribution Function (CCDF)Physical and Environmental SpecificationsRF Power Ra

Pagina 43

Bird Technologies36Limited WarrantyAll products manufactured by Seller are warranted to be free from defects in material and workmanship for a period

Pagina 44 - Bird 5012 Wideband Sensor

iiiNote: NOTE: Calls attention to supplemental informa-tionWarning StatementsThe following safety warnings appear in the text where there is danger to

Pagina 45 - Peak Envelope Power

Bird Model 5000-EX Digital Power MeterivSafety StatementsUSAGEANY USE OF THIS INSTRUMENT IN A MANNER NOT SPECIFIED BY THE MANUFACTURER MAY IMPAIR THE

Pagina 46 - Maximum Peak Power

vANULAR LA PROTECCIÓN DE SEGURIDAD DEL INSTRUMENTO.BENUTZUNGWIRD DAS GERÄT AUF ANDERE WEISE VERWENDET ALS VOM HERSTELLER BESCHRIEBEN, KANN DIE GERÄTES

Pagina 47

Bird Model 5000-EX Digital Power MeterviUTILISATIONTOUTE UTILISATION DE CET INSTRUMENT QUI N’EST PAS EXPLICITEMENT PRÉVUE PAR LE FABRICANT PEUT ENDOMM

Pagina 48 - Limited Warranty

viiZUR VERMEIDUNG GEFÄHRLICHE, ELEKTRISCHE SCHOCKS, SIND WARTUNGSARBEITEN AUSSCHLIEßLICH VON QUALIFIZIERTEM SERVICEPERSONAL DURCHZUFÜHREN.ENTRENTIENL’

Comentarios a estos manuales

Sin comentarios