Maintenance
29
Match Measurement
Measurement Range
Return Loss
Rho (
ρ)
VSWR
0 to 20 dB
0.1 to 1
1.22 to 99.99
Uncertainty Calculated from forward and
reflected uncertainty.
Twice the Avg Power Uncertainty
Settling Time, Max 2.5 seconds
Impedance, Nominal 50 ohms
Insertion Loss, Max 0.05 dB up to 1 GHz
Input VSWR, Max. 1.05:1 up to 1 GHz
Directivity, Typical* 30 dB
RF Connectors QC Type, N(F) normally supplied
Power Supply From host instrument via cable
Mechanical Shock and
Vibration
In accordance with MIL-T-28800D
Class 3
CE CE compliant. Refer to DOC for
specific standards.
Temp, Operating –10 to +50 °C (+14 to +122 °F)
Temp, Storage –40 to +75 °C (–40 to +167 °F)
Humidity, Max 95% (non-condensing)
Altitude, Max 3,000 m (10,000 ft.)
Dimensions, Nominal 2.5” x 5.0” x 2.0”
(59 x 127 x 51 mm)
Weight, Nominal 1.25 lb. (0.6 kg)
* Exact value depends on element selected
Above 35 °C or below 15 °C add 2%